The options of extraction are used by PilotAssembly during the construction of the table.

It is enough to possibly check or not to check certain options and to inform filters.

To force the resolution of the low-fat components : to force or not the reconstruction of the components if they are in a state reduced in the tree of assembly.

To extract the contents from the removed components : allows to recover information of the components even if they are in a “Suppressed” state.

To extract all the occurrences from the components : allows to recover, with the reading, the number of all the repetitions or occurrences present as of the assembly.

To display the components : recovery of all the components (part and assembly). This option is checked by default.

To display the dimensions : recovery or not of the dimensions of the parts. For example to filter only the dimensions of ray and the dimensions of diameter.

To display the aggregate variables : recovery or not of the aggregate variables of the file.

To display the properties : recovery or not of the properties of file, possibility of recovering only certain properties.

To display the Constraints : recovery or not of the constraints of assembly.

To display the properties of the welded specifications : recovery of the properties of the welded articles, possibility of recovering only certain properties.

To display the functions : recovery or not of all the functions of the parts, possibility of recovering only certain functions.

To traverse only the first level of components : allows to block the reading of the assembly on the first level of the assembly.

Alarm in reading if the table is not empty : allows to display a warning message after having clicked on the button reading if the Excel sheet is not empty.

To extract each configuration used : allows to separate all the configurations from the same component used in the assembly (for example a screw used several times in different configurations).

To recover the evaluated values of the properties : allows to recover the value of the properties as calculated, examples:

    • A dimension “D1@Esquisse2” equal to ''20'', PilotAssembly will recover the value ''20''.
    • A property recovering the material “SW-Material@fichier.SLDPRT” of a component in “galvanized Steel”, PilotAssembly will recover the value ''Galvanized Steel''.